Quasi-1D Nozzle Flow

In a duct where the cross-sectional area varies slowly, we can treat the flow as quasi-one-dimensional: all flow properties are uniform across each cross-section and vary only axially. The entire Mach number distribution is then essentially governed by the conservation of mass flow.

$$\begin{gather} \flow \dot{m} = \state \rho \cdot \state u \cdot \geom A = \Frac{\state p}{\gas R \state T} \cdot \mach M \plain\sqrt{\gas \gamma \gas R \state T} \cdot \geom A \\ \vdots \\[8pt] D({\mach M}\plain) \plain = \Frac{\flow \dot{m}}{\geom A} \plain \cdot \Frac{\plain\sqrt{\stag T_t}}{\stag P_t} = \sqrt{\Frac{\gas \gamma}{\gas R}} {\mach M} \plain \left(1 + \frac{{\gas \gamma}-1}{2}{\mach M}^2\right)^{-\frac{1}{2}\frac{{\gas \gamma}+1}{{\gas \gamma}-1}} \\[8pt] \small \flow\mathrm{Mass\ flow} \plain\mathrm{\ per\ } \geom\mathrm{unit\ area} \plain\mathrm{,\ normalized\ by\ } \stag\mathrm{total\ conditions} \plain\mathrm{\ for\ } \gas\mathrm{a\ given\ gas} \plain\mathrm{,\ is\ a\ function\ only\ of\ } \mach\mathrm{Mach\ number} \end{gather}$$

Demo 1 — Subsonic Flow & Throat Choking

Subsonic

Reduce the back-pressure ratio $P_b/P_t$ and watch the Mach number grow. When $P_b/P_t$ reaches a critical ratio, the throat becomes sonic ($M=1$) and mass flow is maximised — further reductions in downstream pressure have no effect.

$M_\text{th}$
—
$M_e$
—
$P_e / P_t$
—
$P_e$
—Pa
$u_\text{th}$ (throat)
—m/s
$\dot{m}/A_\text{th}$
—kg/s/m²
$\dot{m}/\dot{m}^*$
—
Subsonic (M < 0.8)
Transonic (0.8 ≤ M ≤ 1.2)

Reservoir Conditions

$P_t$ (upstream total pressure) 2.0 atm
$T_t$ (upstream total temperature) 298 K
Gas / $\gamma$
Back Pressure  $P_b / P_t$ 1.00

Critical (choke): P_b/P_t = —

Optional chart lines
Nozzle overlays

Demo 2 — Normal Shocks & Full Pressure Range

Shock in Nozzle

Once the throat is choked, two continuous (shock-free) solutions exist: one fully subsonic in the diverging section ($P_b = P_{b,\text{choke}}$) and one fully supersonic ($P_b = P_{b,\text{design}}$). For any back pressure between these two limits, a normal shock stands inside the diverging section. The shock location is set by $P_b$: weaker (nearer throat) for high $P_b$, stronger (nearer exit) for low $P_b$.

$M_\text{th}$
—
$M_e$
—
$P_e / P_{t_0}$
—
$M_1$ (shock)
—
$M_2$ (shock)
—
$\Delta P_t / P_{t_0}$
—
Normal shock at x = — px  |  Upstream M: —  →  Downstream M: —  |  Total pressure recovery: —
Subsonic
Transonic
Supersonic
Normal Shock
Back Pressure  $P_b / P_t$ 1.0

Choke: —  |  Design: —